Electrical/Board/Eyes

IT'S NOT TURNING ON!

(Following is taken from the Dam Manual)

  • Make sure battery is new and well charged.
  • Check that battery dongle is connected to the DAM'" Circuit board
  • Make sure there is no dirt or debris blocking the button from being pressed.
DAM WILL TURN ON / OFF BY ITSELF OR THE EYES WILL TURN ON / OFF BY THEM SELVES

(Following is taken from the Dam Manual)

  • Both of these problems are caused because the button(s) are being held down, as if they are pressed all the time.
  • Remove board from the frame by removing the grip frame, disconnecting the cables and removing the board. Carefully remove the circuit board buttons and clean them well.
  • Re-assemble and test. If problems persist, contact authorized service centre.
DAM TURNS ON, THEN OFF AGAIN RIGHT AWAY/TURNS OFF TRYING TO SHOOT FIRST SHOT

There are two potential causes to this issue.

  1. Battery is low/dead. Swap it with another, or test existing battery with a battery tester, or if you're on the field, stick the 9 9 volt terminals on your tongue and see if it still has some zap to it. [DURACELL batteries have proven to be the least troublesome batteries, DO NOT use generic/no name brand batteries, as they have proven to cause issues in performance]
  2. Connection issue between the battery and the board. The battery harness is not properly seated in the board. Take the lower/grip off the body and reconnect. The poor connection starves the marker of energy and turns off.  [If you are unsure about doing this, please watch video titled "DYE DAM FULL TEAR DOWN, and then watch DYE DAM FULL REBUILD". Only watch parts relating to the gun grip, you don't have to take the whole thing apart just for this step.